Determination of APTT factor sensitivity - The misguiding guideline
Actin FS and Actin FSL (Siemens Healthcare Diagnos-. tics, Marburg, Germany) [ 3]. ... plasma from Siemens, lyophilized factor-deficient and. reference plasmas ...
ijlh12109.pdf
Comparison of the effects of apixaban and rivaroxaban on
Aug 22, 2014 ... (Siemens), STA Neoplastine C1 Plus, TriniCLOT Excel S. (Stago Diagnostica) ... The APTT reagents included Actin FSL (Siemens),. Actin FS ...
pdf
PDF(302K) - Wiley Online Library
Aug 14, 2012 ... obtained with SL, EA, SLA, FSL, SP and PTT were 12.9,. 11.5, 13.2, 15.6, 14.3 ... Corporation, Kobe, Japan), Actin FSL (FSL; Siemens Health-.
pdf
GTH 2013 CS5100(Final) - Siemens A/S
System* (Siemens Healthcare Diagnostics, CS-5100) to the mid-volume blood coagulation analyzer Sysmex® ... Dade Actin FSL/ Standard Human Plasma.
CS5100_CS2100i Poster_Feb2013.pdf
ADG213 - Sekisui Diagnostics
APTT (Siemens Actin FSL). XXX sec. Fibrinogen (clottable). XXX g/L α2- Antiplasmin antigen (ELISA) < XXX U/ml. Application. For research assays of alpha-2 ...
ADG213_25092015_Lot.pdf
Online Supplementary Material
Siemens BCS-XP Siemens Actin FSL. Siemens. Lab 5. Siemens BCS-XP Siemens Actin FSL. 3rd WHO IS. Labs 6–8. Siemens BCS-XP Siemens Actin FSL .
TH112.5_Sommer_supplementary_material.pdf
Determination of APTT factor sensitivity the - Semantic Scholar
Apr 12, 2013 ... Actin FS and Actin FSL (Siemens Healthcare Diagnos- tics, Marburg, Germany) [ 3]. Collection of clinical samples from patients with a single ...
56abe4cacb169cd13746f55f61b747b02c0c.pdf
PDF (125 KB) - Pathology - The Royal College of Pathologists of
instructions. Reagents for aPTT assays included Dade Actin FS/FSL Activated. PTT reagents (Siemens Healthcare Diagnostics Products), TriniCLOT aPTT.
pdf
Hemostasis Reagents Portfolio
Siemens Healthcare Diagnostics Inc. Sysmex ... www.siemens.com/diagnostics ... Dade Actin FSL Activated PTT Reagent exhibits increased sensitivity to lupus ...
Portofoliu_reactivi_hemostaza.pdf
Linköping University Post Print
medicine in Sweden (EQUALIS). The activated partial thromboplastin time (APTT ) was assayed using 5 different reagents: Actin FSL from Siemens Healthcare ...
FULLTEXT01.pdf
fulltext - DiVA
reagents; Actin FSL from Siemens Healthcare Diagnostics (Deerfield, IL, ... Siemens Healthcare Diagnostics, whereas the Stachrom ATIII test was run on the .
FULLTEXT01.pdf
Eximius Control PLUS - medirox
Siemens PT Innovin. INR. 2,63. 2,18-3,08. Siemens ... Siemens Actin FS. Seconds. -. -. Sclavo APTT ... FIX B4219-1 Dade Actin FSL. IU/mL. N/A. N/A. 0,11. N/A.
16018-MRX183.pdf
Downloaded
Sep 18, 2014 ... reagents, Actin FSL® was the least sensitive to dabigatran while the .... ombinant human thromboplastin: Innovin® (Siemens Healthcare.
th_2014_112_20140918_23390.pdf
Method Questionnaire - RIQAS
DAL. Siemens/Dade Actin FSL. DGF. Diagon Dia-F. DP. Siemens/Dade Pathromtin SL. HAE. Helena APTT ES. STA. Stago aPTT. IHA. HemosIL APTT-SP liquid.
Q-RQ9135eng.pdf
0 - casss
APTT. Dutch Diagnostics. Animal. Silica. Actin FS. Siemens. Soy. Ellagic acid. Actin FSL. Siemens. Soy, rabbit brain. Ellagic acid. APTT ES. Helena. Rabbit brain.
2014_WCBP_Peter_Turecek.pdf
Workshop report - European Medicines Agency - Europa
Jun 26, 2014 ... Proposed to label with one-stage for potency using Actin FSL reagent. ..... One stage clotting assay with Siemens Actin reagent (ellagic acid) ...
WC500169760.pdf
January 26, 2016 Siemens Healthcare Diagnostics Products GmbH
Jan 26, 2016 ... Siemens Healthcare Diagnostics Products GmbH .... Thromboplastin Time (APTT ) with Dade® Actin® FSL; Fibrinogen (Fbg) with Dade® ...
K151259.pdf
February - Wadsworth Center
Feb 1, 2016 ... 26.20 ± 0.88 49.23 ± 1.43 30.81 ± 1.54 72.66 ± 2.09 30.77 ± 1.73 n = 68 [AD4] Siemens Actin FSL. 26.39 ± 1.42 48.54 ± 1.38 31.28 ± 1.04 ...
1602hemefull.pdf
June - Wadsworth Center
Jun 8, 2015 ... 25.85 ± 0.82 25.86 ± 0.89 48.95 ± 1.73 72.00 ± 2.69 30.25 ± 1.56 n = 111 [AD4] Siemens Actin FSL. 26.74 ± 0.99 27.34 ± 0.98 48.87 ± 1.32 ...
1506hemefull.pdf
Share on: Siemens Actin Fsl Similar PDF's
Sponsored High Speed Downloads
-
Download Siemens Actin Fsl -
US Mirror Server
- 3532 dl's @ 1277 KB/s
-
Download Siemens Actin Fsl -
Japan Mirror Server
- 2216 dl's @ 3223 KB/s
-
Download Siemens Actin Fsl -
EU Mirror Server
- 2777 dl's @ 1061 KB/s